BIOMOD 2026 / aQtSOME / COMPUTATIONAL STUDY
MscL Gating Simulation.
1. Background
In aQtSOME, GUVs that reach the vicinity of a tumor boundary are squeezed by the surrounding tissue, and the resulting membrane tension opens mechanosensitive (MS) channels in their membranes. Because membrane tension cannot be measured inside living tissue, we built a physical model of the whole process and tested two questions:
- Does the squeezing raise the membrane tension to the value needed to open the channels?
- Do the channels open before the membrane ruptures?
Both hold, even under the conservative condition that the membrane must withstand the tension for several hours. All results can be reproduced with the simulator in Section 4.
Channel assumed: MscL Q56P. Q56P is a mutant of MscL with a single amino-acid substitution, and it opens at two-thirds of the wild-type tension (Blount et al., 1996). The wild-type opening tension (11.8 pN/nm) exceeds the tension a membrane can withstand for long periods, so this simulation assumes Q56P. All results below refer to Q56P.
2. Model overview
3.1Tissue stress
Tumor growth creates stress in the surrounding tissue
3.2GUV deformation
The stress flattens the GUV
3.3Membrane tension
The added membrane area creates tension
3.4Opening or rupture
Which threshold does the tension reach first?
- Stress in the tumor's radial direction (compression)
- Stress along the tumor surface (tension)
- Δσ
- Their difference, . Only this difference changes the GUV's shape (the input of the model)
- Aspect ratio of the GUV (long diameter ÷ short diameter)
- Membrane tension
- Tension at which the channels open (effective opening tension, 3.4)
- Tension at which the membrane ruptures (lysis tension, 3.4)
Every link from stress to shape to tension is monotonic, so the harder the squeezing, the higher the tension. Therefore, if , the channels open first. The stress at the tumor boundary far exceeds the value needed for opening and decreases continuously with distance from the boundary. A GUV approaching the tumor therefore always passes through a range of Δσ in which it opens and does not rupture. We call this range the opening window.
3. Calculation of each stage
3.1 Tumor growth creates stress in the surrounding tissue
- ,
- Shear modulus and Poisson's ratio of normal tissue (10 kPa, 0.2)
- Radius of the undeformed GUV (2.5 µm)
The stress values were read from Fig. 1B of Stylianopoulos (2017), which shows the predictions of a finite-element model of tumor growth (Stylianopoulos et al., 2013). and are also taken from that model.
| Time point | Peak circumferential stress | Radial stress at the same position | Δσ |
|---|---|---|---|
| Day 2 | about +15 kPa | about −24 kPa | about 40 kPa |
| Day 6 | about +33 kPa | about −28 kPa | about 60 kPa |
| Day 8 | about +66 kPa | about −30 kPa | about 96 kPa |
Δσ falls to a few kPa within about 0.5–2 mm into the normal tissue. This distance is far longer than a GUV (about 5 µm), so the tissue around a GUV can be treated as uniformly stressed.
With its liquid interior, a GUV cannot resist the squeezing and deforms immediately according to the Δσ where it arrives. We therefore take the moment of arrival as the spherical reference state.
3.2 The stress flattens the GUV
- ,
- Long and short semi-axes of the flattened GUV ()
- Strength of the membrane's resistance to deformation; larger for smaller GUVs
Style, Wettlaufer and Dufresne (2015) extended Eshelby's (1957) theory of ellipsoidal regions in elastic solids to liquid droplets with surface tension. Applying their solution to our loading gives:
The second term in the denominator is the membrane's resistance. The equation reduces to Eshelby's classical result for and to Eq. 7 of Style et al. for , and it agrees with their general solution to machine precision. Because the tension of a fluid membrane is the same everywhere, the equilibrium shape is obtained by inserting the current , even though the tension rises as the GUV deforms.
The in the denominator is set by the deformation, and the deformation is set by , so shape and tension are determined together. We therefore calculate backward, starting from the tension (Fig. 6).
- Eshelby tensor. Determined by the GUV's shape and the Poisson's ratio, it links the change in shape to the surrounding strain
This type of theory has been shown to match measured droplet shapes up to far-field strains of 42% (Style et al., 2015, Nat Phys). In our calculation, opening and rupture occur at far-field strains of about 0.18–0.22, within that range.
3.3 The added membrane area creates membrane tension
- Relative increase in membrane area
- Bending rigidity of the membrane (how hard the undulations are to smooth out)
- Area stretching modulus (how hard the membrane itself is to stretch)
- Tension before deformation (an osmotically balanced, nearly tension-free GUV; 0.001 pN/nm)
We calculate exactly from the surface area of an oblate spheroid at constant volume and convert it to tension with the relation measured by Evans and Rawicz (1990):
Here is the membrane area, is the thermal energy and is a constant for quasi-spherical vesicles. The first term is the contribution of the undulations and the second that of stretching. Reaching 5 pN/nm requires a total area increase of 4.1%, compared with 2.5% from stretching alone. Including the undulations increases the deformation and stress required, so this term works against opening, not for it. The membrane is assumed to consist of DOPC only ( = 200 pN/nm).
3.4 Does tension reach opening or rupture first?
- Number of channels per GUV (1,000)
A GUV approaching the tumor is exposed for a long time to a slowly rising tension. We therefore set to 5 pN/nm, the tension a membrane can withstand for several hours.
- Half-activation tension of a single channel (Q56P: 7.9 pN/nm, Zhang et al., 2016)
- ,
- Probability that one channel is open, and probability that at least one of channels is open
- Tension at which reaches 50%
The curves in Fig. 11 were calculated with the two-state Boltzmann equation routinely used in patch-clamp experiments:
Here is the change in membrane area on opening, which sets how steeply the curve rises (6.5 nm², the wild-type value from Sukharev et al., 1999).
In this simulation, a GUV is defined as "open" when any one of its channels is open. Because GUVs can be expected to be administered in large numbers rather than singly, we use as the opening criterion the point at which the probability that at least one channel in a GUV is open reaches 50%. Rupture is judged by whether the tension reaches . MscS was excluded because it inactivates under slowly rising tension (Akitake et al., 2005).
4. The simulator
Changing the channel type, the GUV diameter and the number of channels shows how the opening window moves. The Δσ slider corresponds to the distance from the tumor.
Illustration: the larger Δσ, the closer to the tumor (distance is schematic). The GUV shape reflects the calculated aspect ratio.
Fixed values (same as the figures in 5. Results): G = 10 kPa, ν = 0.2, KA = 200 pN/nm, κ = 0.9 × 10⁻¹⁹ J, τ0 = 0.001 pN/nm, τlys = 5 pN/nm, ΔA = 6.52 nm², T = 310 K
5. Results
As Δσ increases, the curve in Fig. 12 first crosses the opening-tension line and then the lysis-tension line. The key values are listed below.
| Effective opening tension | 3.1 pN/nm (about 60% of the lysis tension) |
|---|---|
| Opening window (Δσ) | 4.3–5.3 kPa (about 0.5–2 mm from the boundary) |
| Probability of being open when the lysis tension is reached | about 100% |
| Interface stress ÷ stress needed to open | 9–22× |
An opening window exists at every diameter from 1 to 20 µm. Smaller GUVs have a wider window that is shifted to higher stress; the stress required is at most about 9 kPa.
An opening window appears at about 58 channels or more, and the more channels, the further the window extends toward lower stress.
6. Discussion
6.1 What the results mean
Opening precedes rupture. The effective opening tension of a GUV with 1,000 Q56P channels (3.1 pN/nm) is below the lysis tension the membrane withstands for hours (5 pN/nm). The relation holds even with this long-holding value rather than the lysis tension from short tests (8–10 pN/nm).
A GUV does not need to stay inside the opening window. Fig. 15 shows how a GUV approaches the tumor.
Before opening (①), the tension is below the lysis tension, so the membrane does not rupture however long the approach takes. When the tension reaches the opening tension (②), the channels open immediately. The width of the opening window shows that point ② lies before rupture; it is not a range in which the GUV has to stay.
The conclusion is robust to uncertainties in tissue mechanics. The interface stress is 9–22 times the stress needed to open. Uncertainties in tissue stiffness, Poisson's ratio, the stiffness of the GUV's contents and the lipid composition all shift the opening and rupture points in the same direction, and their effects are smaller than this margin (Appendix A12). The condition is also satisfied over a wide range: diameters of 1–20 µm and 58 or more channels.
6.2 Proposals for the aQtSOME design
- Channel: use an MscL mutant with a lowered opening tension, such as Q56P. When long-lasting loading is assumed, a low opening tension decides whether the condition is met. Do not use MscS, which inactivates under slow loading.
- Number of channels: 60 or more per GUV. With 1,000, the margin is about 17 times the minimum, enough to absorb variation in reconstitution efficiency.
- GUV diameter: any diameter from 1 to 20 µm works. The current 5 µm is sufficient; making GUVs smaller widens the window but raises the stress needed to open.
- Preparation: match the osmolarity inside and outside the GUVs precisely. An imbalance of only about 1.5 mM (0.5%) inflates a 5 µm GUV to a tension of 5 pN/nm by itself.
7. Appendix
The appendix collects the following material omitted from the main text:
- List of symbols and default values
- All equations used for the calculations and decisions
- Derivations and numerical methods for the Eshelby tensor, the solution of Style et al. and the treatment of large deformations
- How the supporting numbers in the main text were obtained, and verification
- Assumptions and open issues of the model, and approximations in the calculation