← Back to Simulation

BIOMOD 2026 / aQtSOME / COMPUTATIONAL STUDY

MscL Gating Simulation.

1. Background

Tumor (tumor cells)Normal cells, compressed near the tumorNormal cellsGUV, flattenedGUV, sphericalCapillaryInterstitium
Fig. 1. The situation modeled in this simulationGUVs that have reached the tissue near a tumor are squeezed by the surrounding tissue. Close to the tumor, they are flattened, with the short axis pointing toward the tumor center.

In aQtSOME, GUVs that reach the vicinity of a tumor boundary are squeezed by the surrounding tissue, and the resulting membrane tension opens mechanosensitive (MS) channels in their membranes. Because membrane tension cannot be measured inside living tissue, we built a physical model of the whole process and tested two questions:

  1. Does the squeezing raise the membrane tension to the value needed to open the channels?
  2. Do the channels open before the membrane ruptures?

Both hold, even under the conservative condition that the membrane must withstand the tension for several hours. All results can be reproduced with the simulator in Section 4.

Channel assumed: MscL Q56P. Q56P is a mutant of MscL with a single amino-acid substitution, and it opens at two-thirds of the wild-type tension (Blount et al., 1996). The wild-type opening tension (11.8 pN/nm) exceeds the tension a membrane can withstand for long periods, so this simulation assumes Q56P. All results below refer to Q56P.

2. Model overview

TumorσrrσθθΔσ = σθθ − σrr

3.1Tissue stress

Tumor growth creates stress in the surrounding tissue

k

3.2GUV deformation

The stress flattens the GUV

Low tension: undulations smoothedHigh tension: membrane stretchesτ

3.3Membrane tension

The added membrane area creates tension

τopenτlysττopen < τlys: opens first

3.4Opening or rupture

Which threshold does the tension reach first?

3.2 and 3.3 affect each other and are determined together, as the balance between the squeezing force and the membrane pulling back
σrr
Stress in the tumor's radial direction (compression)
σθθ
Stress along the tumor surface (tension)
Δσ
Their difference, σθθ−σrr. Only this difference changes the GUV's shape (the input of the model)
k
Aspect ratio of the GUV (long diameter ÷ short diameter)
τ
Membrane tension
τopen
Tension at which the channels open (effective opening tension, 3.4)
τlys
Tension at which the membrane ruptures (lysis tension, 3.4)
Fig. 2. The four stages of the model

Every link from stress to shape to tension is monotonic, so the harder the squeezing, the higher the tension. Therefore, if τopen<τlys, the channels open first. The stress at the tumor boundary far exceeds the value needed for opening and decreases continuously with distance from the boundary. A GUV approaching the tumor therefore always passes through a range of Δσ in which it opens and does not rupture. We call this range the opening window.

3. Calculation of each stage

3.1 Tumor growth creates stress in the surrounding tissue

TumorNormal tissue (G, ν)σrr: pushed radially (compression)σθθ: stretched along the surface (tension)GUV (2R ≈ 5 µm)The growing tumorpushes outwardΔσ = σθθ − σrr40–96 kPa at the interface,lower farther out
G, ν
Shear modulus and Poisson's ratio of normal tissue (10 kPa, 0.2)
R
Radius of the undeformed GUV (2.5 µm)
Fig. 3. Stress at the tumor boundaryNormal tissue at the boundary is compressed radially and stretched along the tumor surface. Their difference Δσ flattens the GUV into a disk whose short axis points radially.

The stress values were read from Fig. 1B of Stylianopoulos (2017), which shows the predictions of a finite-element model of tumor growth (Stylianopoulos et al., 2013). G and ν are also taken from that model.

Time pointPeak circumferential stressRadial stress at the same positionΔσ
Day 2about +15 kPaabout −24 kPaabout 40 kPa
Day 6about +33 kPaabout −28 kPaabout 60 kPa
Day 8about +66 kPaabout −30 kPaabout 96 kPa

Δσ falls to a few kPa within about 0.5–2 mm into the normal tissue. This distance is far longer than a GUV (about 5 µm), so the tissue around a GUV can be treated as uniformly stressed.

Equal pressure from all sidesFixed volume: shape unchanged(only the internal pressure rises)Directional difference ΔσFlattens(only this changes the shape)
Fig. 4. Stresses that do and do not change the shapeA GUV keeps its volume through osmotic balance, so a pressure equal in all directions (including interstitial fluid pressure) does not change its shape. Only the directional difference Δσ does.

With its liquid interior, a GUV cannot resist the squeezing and deforms immediately according to the Δσ where it arrives. We therefore take the moment of arrival as the spherical reference state.

3.2 The stress flattens the GUV

2c2aRτSqueezing forceΔσ vs. tissue stiffness G, νRestoring forceTension τ: membrane pulls back(stronger for smaller R: τ/R)Equilibrium shapek = a/c at fixed volumeDashed: undeformed sphere
a, c
Long and short semi-axes of the flattened GUV (k=a/c)
τ/R
Strength of the membrane's resistance to deformation; larger for smaller GUVs
Fig. 5. GUV deformation and membrane resistanceThe GUV's shape is set by the balance between the tissue squeezing it and the stretched membrane pulling back.

Style, Wettlaufer and Dufresne (2015) extended Eshelby's (1957) theory of ellipsoidal regions in elastic solids to liquid droplets with surface tension. Applying their solution to our loading gives:

ln⁡k≈15(1−ν)Δσ2(7−5ν)G+(17−19ν)τR

The second term in the denominator is the membrane's resistance. The equation reduces to Eshelby's classical result for τ→0 and to Eq. 7 of Style et al. for ν=1/2, and it agrees with their general solution to machine precision. Because the tension of a fluid membrane is the same everywhere, the equilibrium shape is obtained by inserting the current τ, even though the tension rises as the GUV deforms.

The τ in the denominator is set by the deformation, and the deformation is set by τ, so shape and tension are determined together. We therefore calculate backward, starting from the tension (Fig. 6).

Choose tension τArea increase αEvans–Rawicz (3.3)Shape kGeometry (3.3)Needed stress ΔσEquation of 3.2Repeat while raising τ from 0 to the lysis tension → result curve (Section 5)
Fig. 6. Calculation flowThe simulator, which takes Δσ and returns the tension, reads this relation in reverse. The equations and numerical methods are given in Appendix A2–A5.
k = 1.00Compute Sk = 1.15Compute Sk = 1.30Compute Sk = 1.45Compute Sk = 1.60Compute S
S
Eshelby tensor. Determined by the GUV's shape and the Poisson's ratio, it links the change in shape to the surrounding strain
Fig. 7. Treatment of large deformationsThe stress is increased in small steps, and S is recalculated for the current shape at each step as the deformation accumulates (the method of Bilby, Eshelby and Kundu, 1975).

This type of theory has been shown to match measured droplet shapes up to far-field strains of 42% (Style et al., 2015, Nat Phys). In our calculation, opening and rupture occur at far-field strains of about 0.18–0.22, within that range.

3.3 The added membrane area creates membrane tension

τ ≈ τ0Undulatedτ lowSmoothed out (κ)τ highStretched (KA)+α+α
α
Relative increase in membrane area
κ
Bending rigidity of the membrane (how hard the undulations are to smooth out)
KA
Area stretching modulus (how hard the membrane itself is to stretch)
τ0
Tension before deformation (an osmotically balanced, nearly tension-free GUV; 0.001 pN/nm)
Fig. 8. Membrane area and tensionAt low tension, smoothing out the membrane undulations supplies area, so the tension rises slowly. At high tension, the membrane itself stretches and the tension rises steeply.

We calculate α exactly from the surface area of an oblate spheroid at constant volume and convert it to tension with the relation measured by Evans and Rawicz (1990):

α=kBT8πκln⁡(1+cτA/κ1+cτ0A/κ)+τ−τ0KA,c=124π

Here A is the membrane area, kBT is the thermal energy and c is a constant for quasi-spherical vesicles. The first term is the contribution of the undulations and the second that of stretching. Reaching 5 pN/nm requires a total area increase of 4.1%, compared with 2.5% from stretching alone. Including the undulations increases the deformation and stress required, so this term works against opening, not for it. The membrane is assumed to consist of DOPC only (KA = 200 pN/nm).

3.4 Does tension reach opening or rupture first?

N channelsτopenτlysMembrane tension τRising tension: τopen first → opens; τlys first → ruptures
N
Number of channels per GUV (1,000)
Fig. 9. Opening or ruptureAs the GUV is squeezed, the membrane tension rises. The outcome depends on whether it reaches τopen or τlys first.
051015Membrane tension [pN/nm]Rupture in short testsSurvives for hours: up to 5 pN/nmFails within 0.1 sOur criterion: no rupture below
Fig. 10. Lysis tension and holding timeMembrane rupture is a stochastic process in which a pore created by thermal fluctuations grows, so the longer the tension is held, the lower the tension at which rupture occurs (short tests: Rawicz et al., 2000; long holding times: Evans and Smith, 2011, for SOPC).

A GUV approaching the tumor is exposed for a long time to a slowly rising tension. We therefore set τlys to 5 pN/nm, the tension a membrane can withstand for several hours.

00.51024681012Membrane tension τ [pN/nm]Open probabilityτlys = 5τopen = 3.1One channel(Popen; T1/2 = 7.9)At least one of1,000 channels (Pany)
T1/2
Half-activation tension of a single channel (Q56P: 7.9 pN/nm, Zhang et al., 2016)
Popen, Pany
Probability that one channel is open, and probability that at least one of N channels is open
τopen
Tension at which Pany reaches 50%
Fig. 11. Channel number and open probabilityWith 1,000 channels, one of them opens at a far lower tension than with a single channel.

The curves in Fig. 11 were calculated with the two-state Boltzmann equation routinely used in patch-clamp experiments:

Popen(τ)=11+exp⁡[−ΔA(τ−T1/2)kBT],Pany(τ)=1−(1−Popen(τ))N

Here ΔA is the change in membrane area on opening, which sets how steeply the curve rises (6.5 nm², the wild-type value from Sukharev et al., 1999).

In this simulation, a GUV is defined as "open" when any one of its channels is open. Because GUVs can be expected to be administered in large numbers rather than singly, we use as the opening criterion the point at which the probability that at least one channel in a GUV is open reaches 50%. Rupture is judged by whether the tension reaches τlys. MscS was excluded because it inactivates under slowly rising tension (Akitake et al., 2005).

4. The simulator

Changing the channel type, the GUV diameter and the number of channels shows how the opening window moves. The Δσ slider corresponds to the distance from the tumor.

Membrane tension τ
—
Probability that at least one is open
—
Membrane tension Effective opening tension τopen Lysis tension τlys Opening window

Illustration: the larger Δσ, the closer to the tumor (distance is schematic). The GUV shape reflects the calculated aspect ratio.

Fixed values (same as the figures in 5. Results): G = 10 kPa, ν = 0.2, KA = 200 pN/nm, κ = 0.9 × 10⁻¹⁹ J, τ0 = 0.001 pN/nm, τlys = 5 pN/nm, ΔA = 6.52 nm², T = 310 K

5. Results

0123456701234567Deviatoric tissue stress Δσ [kPa]Membrane tension τ [pN/nm]Lysis tension 5 pN/nm (held for hours)Effective opening tension 3.1 pN/nmOpening window 4.3–5.3 kPa
Fig. 12. Membrane tension versus ΔσDOPC GUV, 5 µm in diameter, with 1,000 MscL Q56P channels. The opening window (green) runs from the Δσ where the curve crosses the blue dotted line (opening) to the Δσ where it crosses the red dashed line (rupture). The curve above the lysis tension is drawn faintly.

As Δσ increases, the curve in Fig. 12 first crosses the opening-tension line and then the lysis-tension line. The key values are listed below.

Effective opening tension τopen3.1 pN/nm (about 60% of the lysis tension)
Opening window (Δσ)4.3–5.3 kPa (about 0.5–2 mm from the boundary)
Probability of being open when the lysis tension is reachedabout 100%
Interface stress ÷ stress needed to open9–22×
02468101251020GUV diameter [µm] (log scale)Deviatoric stress Δσ [kPa]Our design: 5 µmRupture (upper edge)Opening (lower edge)Opening window
Fig. 13. GUV diameter and the opening windowMscL Q56P, 1,000 channels. The lower edge of the band is the stress at which the channels open and the upper edge the stress at which the membrane ruptures. Inside the band, a GUV opens its channels without rupturing.

An opening window exists at every diameter from 1 to 20 µm. Smaller GUVs have a wider window that is shifted to higher stress; the stress required is at most about 9 kPa.

024681101001,00010,000Channels per GUV, N (log scale)Deviatoric stress Δσ [kPa]Rupture 5.32 kPa (5 pN/nm)Stress needed to openOpens first for N ≥ 58Assumed: 1,000Opening window
Fig. 14. Channel number and the stress needed to openDiameter 5 µm. The green region is the opening window (at or above the opening stress and below the rupture stress), with the same meaning as in Fig. 13.

An opening window appears at about 58 channels or more, and the more channels, the further the window extends toward lower stress.

6. Discussion

6.1 What the results mean

Opening precedes rupture. The effective opening tension of a GUV with 1,000 Q56P channels (3.1 pN/nm) is below the lysis tension the membrane withstands for hours (5 pN/nm). The relation holds even with this long-holding value rather than the lysis tension from short tests (8–10 pN/nm).

A GUV does not need to stay inside the opening window. Fig. 15 shows how a GUV approaches the tumor.

① Approachτ < τopenWell below 5 pN/nm:no rupture, even if slow② Openingτ = τopenChannels open at once(gating is fast)③ After opening(not modeled)τ tends to decreaseSolutes and water leave;tension relaxesΔσ increasesThe hours-long lysis criterion guarantees that the membrane survives stage ①
Fig. 15. What happens as a GUV approaches the tumorOpening occurs at ②, so the GUV does not need to remain inside the opening window. ③, which reflects the role of MscL as a safety valve, is not included in the calculation.

Before opening (①), the tension is below the lysis tension, so the membrane does not rupture however long the approach takes. When the tension reaches the opening tension (②), the channels open immediately. The width of the opening window shows that point ② lies before rupture; it is not a range in which the GUV has to stay.

The conclusion is robust to uncertainties in tissue mechanics. The interface stress is 9–22 times the stress needed to open. Uncertainties in tissue stiffness, Poisson's ratio, the stiffness of the GUV's contents and the lipid composition all shift the opening and rupture points in the same direction, and their effects are smaller than this margin (Appendix A12). The condition is also satisfied over a wide range: diameters of 1–20 µm and 58 or more channels.

6.2 Proposals for the aQtSOME design

  • Channel: use an MscL mutant with a lowered opening tension, such as Q56P. When long-lasting loading is assumed, a low opening tension decides whether the condition is met. Do not use MscS, which inactivates under slow loading.
  • Number of channels: 60 or more per GUV. With 1,000, the margin is about 17 times the minimum, enough to absorb variation in reconstitution efficiency.
  • GUV diameter: any diameter from 1 to 20 µm works. The current 5 µm is sufficient; making GUVs smaller widens the window but raises the stress needed to open.
  • Preparation: match the osmolarity inside and outside the GUVs precisely. An imbalance of only about 1.5 mM (0.5%) inflates a 5 µm GUV to a tension of 5 pN/nm by itself.

7. Appendix

The appendix collects the following material omitted from the main text:

  • List of symbols and default values
  • All equations used for the calculations and decisions
  • Derivations and numerical methods for the Eshelby tensor, the solution of Style et al. and the treatment of large deformations
  • How the supporting numbers in the main text were obtained, and verification
  • Assumptions and open issues of the model, and approximations in the calculation